ModelTrilogy 202
Cpap4 - 20 cmH20 (passive leak port circuits)
Atmospheric Pressure60 - 110 kPa (450 - 825 mmHg)
Relative Humidity15 - 95 %
BrandPhilips
Epap0 - 25 cmH20 (active valve circuits)
Storage temperature-20 to +60 deg C
Ramp time Off5 - 45 min
Timed ventilationYes
DirectView1 GB SD card data storage integrated into the ventilator software
Active exhalation valve with proximal airway pressureYes
Flow trigger sensitivity1 - 9 l/min
High minute ventilation Off1 - 99 l/min Off, 1 - 99 l/min
Low minute ventilation Off1 - 99 l/min
Breath rate0 - 60 BPM (AC mode) beats per minute
Respiratory rate0 - 80 BPM 0 - 80 beats per minute
C Flex Off1 - 3 (relative scale)
Spontaneous ventilationYes
Estimated leak rate0 - 200 l/min
Hospital roll standProvides convenient accessory basket and humidifier mount
IPAP50 cm H2O
MPV Mouthpiece Ventilation ModeYes
Pressure controlYes
Active exhalation valve with flow sensorYes
Inspiratory time0.3 - 5.0 s Synchrony features
High tidal volume Off50 - 2000 ml
Adjustable flow triggering1 - 9 l/min (available in all modes and circuit types) l/min
Oxygen input pressure range276 - 600 kPa (40 - 87 psi)
Flow cycle sensitivity10 - 90 %
Low tidal volume Off50 - 2000 ml
Auto Trak sensitivityAuto-Trak sensitivity Auto-adaptive triggering, cycling, and leak compensation
Rise time1 - 6 (relative scale)
SIMV with pressure supportYes
Peak inspiratory flow0 - 200 l/min
IE ratio9.9:1 - 1:9.9 (I:E)
Pressure support0 - 30 cm H2O
Synchronized intermittent mandatory ventilationYes
Apnea Off10 - 60 s and 4 - 60 BPM
Tidal volume50 - 2000 ml
Percent patient triggered breaths0 - 100 %
Pediatric5 kg or greater
External battery connection12 VDC
AdultYes
Passive exhalation portYes
Continuous positive airway pressureYes
Average volume assured pressure supportYes
Oxygen flush2 min at 100%
Control ventilationYes
Circuit disconnect Off10 - 60 sec
Low respiratory rate Off4 - 80 beats per minute
Spontaneous ventilation with timed back upYes
High respiratory rate Off4 - 80 beats per minute
Pressure control SIMVYes
Minute ventilation0 - 99 l/min
Input voltage100 - 240 VAC and 50/60 Hz and 2.1 A
Ramp start pressure0 - 25 cmH20 (active circuits)
Internal battery Life3 hours under normal conditions hr
Detachable battery life3 hours under normal conditions hr
Operating temperature5 to 40 deg C
Detachable back up batteryOffering up to 3 hours additional operating time
Oxygen21 - 100 % FiO2
Mean airway pressure0 - 99 cm H2O
Peak inspiratory pressure0 - 99 cm H2O
Detachable battery voltage14.4 VDC

The Philips Ventilator is both a volume-control & pressure-control ventilator for invasive and noninvasive ventilation. Versatile breath delivery and setup options provide greater continuity of care.

Features:
  • Leak compensation: The Trilogy 202 has the unique ability to compensate for leaks in both pressure and volume control modes. This allows the use of simpler passive circuits, which may save time and reduce costs. With one simple setting change, the Trilogy 202 supports either active or passive exhalation breathing circuits to accommodate changes in circuit preference.
  • Auto-Trak improves synchrony: The Auto-Trak algorithm improves patient-ventilator synchrony by adjusting to changing breathing patterns and dynamic leaks. The auto-adaptive triggering, cycling, and leak adjustments may help reduce the time clinicians spend adjusting thresholds and re-fitting masks.
  • Uniform settings to support hospital to home transition: Besides sharing a common user interface, all home and hospital Trilogy ventilators offer identical ventilation modes and breathing circuit settings. Home-bound patients receive the same finely tuned ventilatory support they received in the hospital. Stored data can be downloaded for review and evaluated to identify trends.
  • Portable design for intra-hospital transport: The Trilogy 202 allows freedom of movement. With a 3-hour internal battery and optional 3-hour detachable battery, you'll have sufficient power for intra-hospital transports - with plenty of time for any delays or detours. It weighs only 5.6 kg and has an integrated carrying handle for convenient handling during intra-hospital transports.
  • Auto-Trak improves synchrony: The Auto-Trak algorithm improves patient-ventilator synchrony by adjusting to changing breathing patterns and dynamic leaks. The auto-adaptive triggering, cycling, and leak adjustments may help reduce the time clinicians spend adjusting thresholds and re-fitting masks.
  • Leak compensated volume modes to improve consistency: Trilogy 202 offers all the conventional volume-control modes: AC, SIMV (with or without PS), and CV. The Trilogy 202 is designed to compensate for leaks in a volume control mode. This means consistent tidal volume delivery even during noninvasive or when cuff leaks are present.
Yes! I am Interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
R Nataraj (Manager)
Respicure Medical Systems
No 223, 7th Main Road, 3rd A Cross, Maruthi Nagar,Vasanthpura, Subramanyapura
Bengaluru - 560061, Karnataka, India
Call Us: 
Call Response Rate: 100%
Share Us :



Home  |   Profile   |  Products & Services  |  Site Map  |   Contact Us

© Respicure Medical Systems. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Respicure Medical Systems